超吸水聚合物改性混凝土可耐千度高温

虽然自密实混凝土比传统振实混凝土多了许多优点,比如楼房建造时间缩短、设备需求更少、噪音污染低,但当面对火的时候,它就显得不堪一击,墙面出现剥落、开裂最终倒塌。虽然传统意义上的混凝土不会轻易发生燃烧,但当混凝土石屑和石片暴露在火当中之后,它们也会像柴火一样发出爆裂声,这是因为当被困在高温环境下时其内部的水开始蒸发,导致内部结构发生变化进而烧掉这些物质。

以往这个问题以往可以通过添加聚丙烯纤维(PP fiber)来解决,当周围温度升高时,这些纤维融化形成屏障能防止内部水通过蒸发的形式流失。由于把这种PP纤维加到自密实混凝土中会影响到它的自密实性,所以加入的量必须保持在一个非常低的水平,这样才能达到既保持了原始的自密实性又能拥有防火的能力。尽管如此,在大火高温下墙面还是会出现开裂和脱落现象。

现在,瑞典联邦材料科学与技术实验室的科研人员发现通过添加超吸水聚合物(SAP,super absorbing polymer )可明显地提高混泥土的耐火耐高温性能,试验表明混凝土在1000摄氏度下处理90十分钟,未发现开裂和脱落现象。

Wood crackles as it burns in a chimney or campfire. When concrete is exposed to fire it chips and flakes – a process known as spalling. Both effects are due to the same phenomenon: water trapped within the piece of wood or concrete element vaporizes due to the high temperature. As more water vapour is produced the pressure within the wood or concrete structure increases. In wood this causes the cells to burst with a crackling sound, creating cracks in the logs. In concrete structures, chips split away from ceilings, walls, and supporting pillars, reducing their loadbearing capacity and increasing the risk of collapse in a burning building.

The resistance of conventional vibrated concrete to the heat of a fire can be optimized by adding a few kilograms of polypropylene (PP) fiber per cubic meter of concrete mixture. When exposed to fire the fibers melt, creating a network of fine canals throughout the concrete structure. These allow the water vapour to escape without increasing the internal pressure, so the concrete structure remains intact.

Self-compacting high-performance concrete (SCHPC) behaves differently though. Adding more than 2 kg of PP fiber per cubic meter to the SCHPC mixture affects its ability to self-compact, so the proportion of PP fiber in SCHPC must be kept relatively low. This in turn means that if the concrete is exposed to fire, the network of fine canals created by the melting fibers is not continuous throughout the entire structure, allowing spalling to occur. The $64,000 question is therefore how to make SCHPC fire-resistant, so buildings made of it are safer, whilst keeping the proportion of polymer fibers low enough that the concrete remain self-compacting.

Researchers from Empa’s «Concrete / Construction Chemistry» and «Mechanical Systems Engineering» Laboratories have now managed to find an answer. They manufactured a series of thin-walled concrete slabs which were prestressed with cables made of carbon fiber reinforced polymer. The concrete from which the slabs were made also contained 2 kg of PP fiber per cubic meter of mixture. In some slabs the scientists also added a small quantity of super absorbing polymer (SAP), a special synthetic material which is capable of absorbing many times its own weight in water. They then exposed the concrete slabs to fire, reaching temperatures of up to 1000°C. After 90 minutes it became clear that whilst the SAP-containing concrete slabs showed some minor cracking, spalling occurred only in the SAP-free slabs.

The explanation for this behaviour is as follows: during the manufacturing process the SAP is saturated with water, swelling to several times its dry volume. As the concrete is setting the water is drawn out of the SAP by capillary action in the porous cement matrix. The SAP shrinks and creates hollow spaces which link the individual, hitherto unconnected networks of PP fibers. The result is a dendritic network of SAP and PP fibers which permeate the entire volume of concrete, allowing it to tolerate the heat of the fire for sufficiently long to maintain the structural integrity of the building.

With their innovative development the Empa researchers have widened the opportunities for exploiting the economic and environmental advantages offered by self-compacting concrete (SCC). The new process, for which a patent has been applied, allows for instance the use of SCHPC for fire-resistant structures. To date this is only been possible using SCC in combination with a sprinkler extinguishing system or an external thermal insulation layer.

But the new SCHPC boasts an additional advantage – the machines used to compact conventional vibrated concrete generate a considerable amount of noise. Construction companies can now keep the noise level down by using SAP enriched self-compacting high-performance concrete instead of vibrated concrete, without any loss of fire resistance.

Source from:empa.ch&cnbeta.com